Previous Next
Sold on
18/08/15
Winning Bid
US $57,000
Won using Buy Now Price
# of Bids
SOLD!
ITEM DETAILS
Meter Reading
690 Hours
Serial #
Enclosed Cab, Air Conditioner, Heater, Tilt Steering Wheel, 4x4, Backhoe Pilot Controls, Control Pattern Changer, Extendable Stick, 83" Wide GP Bucket, 24" Rear Bucket. ***This unit must be picked up within 15 calendar days of the sale. If not picked up within this time frame, this unit will be subject to relocation/storage costs.***

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
(3)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Operational
Safety Lock Out/Stop


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Drivetrain Controls
Brake Control
Steering Control
Transmission Disconnect Control
Hydraulic Controls
Backhoe Control Configuration Equipped with a control pattern changer
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Warning Lights Operational
Gauges Operational
Hour Meter (pre-inspection) 690 Hours
Hour Meter 690 Hours - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Air Conditioner Operational
Heater Operational
Limited Function Check The main components are in place and operational.
(15)


Engine
Description Rating Details  
Emission Certification Label None found
Engine Serial Number 00093757
A/C Compressor Operational
Blow by @ idle (subjective observation) No noticeable vapor or pressure
Starter Operational
Radiator
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check The engine started and ran.
(10)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational
Front Axle
Front Axle Oscillating Pin
Rear Axle
Final Drives
Limited Function Check The drivetrain was operational.
(8)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics)
Valves
Hydraulic Tank
Loader Lift Cylinders
Bucket Tilt Cylinders
Outrigger Cylinders
Boom Swing Cylinders
Boom Lift Cylinder(s)
Stick Cylinder
Bucket Cylinder
Limited Function Check The hydraulic system was operational.
(12)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Steering Linkage
Master Cylinder
Brake Lines/Hoses
Park Brake
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Frame Condition
Tyre Size 12x16.5NHS Front tires; 19.5L-24 Rear tires; Galaxy & Goodyear
Tire Condition
Wheel Condition
Wheel Studs, Nuts, Lugs
Lift Arm Condition
Chassis to Arm Pins
Tilt Linkage
Tilt Linkage Pins and Bushings
Bucket to Arm Pins
Limited Function Check The main chassis components were operational in a limited check.
Boom Condition
Stick Condition
Stick Extension Wear Guides
Boom Lock (Backhoe)
Swing Tower Pivot
Boom Base Pin and Bushings
Pin and Bushings Boom to Stick
Pin and Bushings Stick to Bucket
Outriggers Street pads
Limited Function Check The main components were operational with damage as noted.
(24)


Specialty
Description Rating Details  
Loader Bucket Condition
Loader Bucket Edge Reversible-not turned
Backhoe / Excavator Bucket Condition
Backhoe / Excavator Bucket Shanks and Teeth Metal welded to teeth
(9)
 

Oil Sample Analysis
  hydraulic transmission
date of analysis Aug 12, 2015 Aug 12, 2015
Lead 0 PPM 0 PPM
Chromium 0.24 PPM 0.38 PPM
Copper 1.29 PPM 15.27 PPM
Silver 0 PPM 0 PPM
Nickel 0.72 PPM 0.58 PPM
Tin 0.55 PPM 0 PPM
Aluminum 1.7 PPM 2.99 PPM
Silicon 9.05 PPM 10.58 PPM
Iron 4.65 PPM 16.75 PPM
Glycol N/A N/A
Water N/A N/A
Fuel N/A N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.