ITEM DETAILS
Meter Reading
3,286 Hours
Serial #
Enclosed Cab, Air Conditioner, Heater, Long Reach Boom & Stick, Wilco W97 Amphibious Undercarriage, 43" Smooth Edge Bucket

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark No
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
(16)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Operational
Safety Lock Out/Stop Click here to open photos and videos of this item.  
Swing Brake Operational
(2)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 3285.1 Hours
Hour Meter 3,286 Hours; Operational hour meter - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner Inoperative Click here to open photos and videos of this item.  
Heater Operational
Current Safety Manual Yes
Current Operator/Maintenance Manual Yes
Limited Function Check The main components are in place and operational.
(16)


Engine
Description Rating Details  
Emission Certification Label None found
A/C Compressor Compressor will not engage; Noisy.
Blow by @ idle (subjective observation) Visible Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks Dripping Leak: Fuel filter. Click here to open photos and videos of this item.  
Cooling System Leaks None seen
Limited Function Check The engine started and ran.
(6)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(3)


Hydraulics
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Swing Motor Click here to open photos and videos of this item.  
Hydraulic Center Swivel Click here to open photos and videos of this item.  
Boom Lift Cylinder(s) Dripping leak on the left cylinder; Dripping leak on the right cylinder Click here to open photos and videos of this item.  
Stick Cylinder Click here to open photos and videos of this item.  
Bucket Cylinder Dripping leak Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(11)


Chassis
Description Rating Details  
Boom Condition Weld repairs Click here to open photos and videos of this item.  
Stick Condition Click here to open photos and videos of this item.  
Boom Base Pin and Bushings Visible movement Click here to open photos and videos of this item.  
Pin and Bushings Boom to Stick Visible movement Click here to open photos and videos of this item.  
Pin and Bushings Stick to Bucket Heavy movement Click here to open photos and videos of this item.  
Turntable Bearing Click here to open photos and videos of this item.  
Bottom Covers Click here to open photos and videos of this item.  
Limited Function Check The main components were operational in a limited check.
(11)


Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Roller Frames Click here to open photos and videos of this item.  
Track Pads Missing/Broken pads; Missing bolts Click here to open photos and videos of this item.  
Track Tensioners No visible damage
Grouser Height 33 mm Click here to open photos and videos of this item.  
Idlers Click here to open photos and videos of this item.  
Sprockets Broken teeth Click here to open photos and videos of this item.  
(13)


Specialty
Description Rating Details  
Excavator Bucket Condition Click here to open photos and videos of this item.  
(5)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Jun 12, 2015 Jun 12, 2015
Lead 1.87 PPM 1.26 PPM
Chromium 1.27 PPM 0.73 PPM
Copper 1.23 PPM 3.73 PPM
Silver 0 PPM 0 PPM
Nickel 1.35 PPM 0 PPM
Tin 0 PPM 0.02 PPM
Aluminum 2.71 PPM 5 PPM
Silicon 0 PPM 19.42 PPM
Iron 23.48 PPM 8.48 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.