ITEM DETAILS
Meter Reading
843 Hours
Serial #
Enclosed Cab, A/C, Heater, Cummins Engine, Powershift, 90' Boom, 1,000 Gal. Tank, 329/85R38 Front Tires, 320/90R50 Rear Tires.

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
(24)


Safety
Description Rating Details  
Seat Belts Operational
Safety Lock Out/Stop Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(2)


Control Station
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 843 Hours Click here to open photos and videos of this item.  
Hour Meter/Odometer (Ending) 843 Hours; Not operationally checked - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner The ambient temperature is too cold to check.
Heater Operational Click here to open photos and videos of this item.  
Limited Function Check (cs) The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(21)


Engine
Description Rating Details  
Emission Control Label (Must Have Legible Photo) US EPA certification label Click here to open photos and videos of this item.  
A/C Compressor In place; ambient temperature too cold to check operation. Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen Click here to open photos and videos of this item.  
Fuel Leaks None seen Click here to open photos and videos of this item.  
Cooling System Leaks None seen Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran.
(12)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Rear Axle Click here to open photos and videos of this item.  
Rear Tandems (Chain Drives) Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check - Rubber Tire The drivetrain was operational.
(12)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Valves Dripping leak Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Cylinders Dripping leak Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check (hydraulic) The hydraulic system was operational.
(19)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Steering Linkage Click here to open photos and videos of this item.  
Brake Type - Backhoe Hydrostatic
Master Cylinder
Brake Control Click here to open photos and videos of this item.  
Park Brake
Limited Function Check (Brakes) The brake system functioned, stopping and holding the machine.
Frame Condition Click here to open photos and videos of this item.  
Tyre Size 320/85R38 Front tires; 320/90R50 Rear tires Click here to open photos and videos of this item.  
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Tread Depth (8 tires) LF 30/32"; LR 30/32"; RR 30/32"; RF 30/32" Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs, Nuts, Lugs
Booms and Boom Tree Click here to open photos and videos of this item.  
Boom Shocks Click here to open photos and videos of this item.  
Tank Click here to open photos and videos of this item.  
Tank Saddle Click here to open photos and videos of this item.  
Plumbing Click here to open photos and videos of this item.  
Electrical
Foam Marker Not operationally checked Click here to open photos and videos of this item.  
Pressure Gauge System Not operationally checked Click here to open photos and videos of this item.  
Controller Operational Click here to open photos and videos of this item.  
(35)
 

Oil Sample Analysis
  engine transmission
date of analysis Jun 22, 2017 Jun 22, 2017
Lead 0 PPM 72.49 PPM
Chromium 1.83 PPM 0.07 PPM
Copper 1.44 PPM 100.58 PPM
Silver 0 PPM 0 PPM
Nickel 0 PPM 0 PPM
Tin 0 PPM 0 PPM
Aluminum 0.09 PPM 1.27 PPM
Silicon 6 PPM 13.27 PPM
Iron 10.23 PPM 43.88 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.