The sheet metal is dented, scraped, and damaged. The right side fender/handrail/step assembly is missing. Surface rust in paint loss areas; The fuel filler access panel latch is broken.
General Appearance #1
Control Station
Steps/Ladders
The left side steps are bent and weld repaired. The right side steps are missing.
Hand Rails
The left side hand rails are bent and weld repaired. The right side hand rails are missing.
Mirrors
Glass
The windshield has been replaced with plexiglas and is scratched.
Seats/Armrests
Dirty
Seat belts
Dirty
Horn
Functional
Control Lock Lever
Disconnect Control
Hydraulic Controls
Stiff
Steering Controls
Powertrain Controls
Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Exterior Lights Functional
Some Inoperable; Some Missing; Some broken
Engine Warning Lights
Functional
Travel Alarm
Functional
Gauges
The fuel gauge is inoperable.
Hour Meter/Odometer (Ending)
17,513 Hours; Functional
- IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Air Conditioner
Functional
Heater
Functional
Limited Function Check (cs)
The main components functioned during a limited check.
Hour Meter/Odometer (Ending)
Engine
Engine Make and Model
Komatsu S6D125-1; Serial #: 77746
Fuel Type (Select)
Diesel
Emission Control Label
None found
Blow by @ idle (subjective observation)
Visible
Starter
Turbo or Blower
Operational
Injector Pump
Operational
Exhaust System
Rust Penetration; Leaks
Radiator
Head Gasket Leaks
Oil seepage
Oil Leaks
There is residue on the oil pan, and sides and front of the engine.
Fuel Leaks
None seen
Cooling System Leaks
None seen
Limited Function Check (Engine)
The engine was operational with leaks. See oil report.
Blow by @ idle (subjective observation)
Drivetrain - Wheel Loader
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Transmission
Torque Converter
Feels normal
Front Axle
Wet with residue
Rear Axle
Residue
Final Drives
Residue
Limited Function Check - Rubber Tire
The drivetrain functioned during a limited check without a load. See oil report.
The hydraulic system performed with wear and leaks as noted. See oil report.
Hydraulics #1
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Steering Linkage
Wear consistent with hours and age
Articulating Center Pins
Wear consistent with hours and age
Steering Wheel Play
Minor
Brake Type
Hydraulic
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Held on slope; Held against power
Limited Function Check (Brakes)
The brake system functioned, stopping and holding the machine.
Frame Condition
A weld repair has been made to the right rear corner of the frame. Rusty
Tire Size (4)
Size: 26.5-25; Brand: Triangle
Tire Condition
Cuts; Low air. There is a piece of steel in the tread area of the right rear tyre.
Tread Depth (4 tires)
LR 29 mm
Wheel Condition
Rusty
Wheel Studs, Nuts, Lugs
Lift Arm Condition
Rusty; Weld repair
Chassis to Arm Pins
Wear consistent with hours and age
Tilt Linkage Pins and Bushings
Wear consistent with hours and age
Bucket to Arms Pins
Wear consistent with hours and age
Limited Function Check (rt machines)
The main components were operational with wear and damage as noted.
Chassis #1
Specialty - Wheel Loader
Loader Bucket Condition
3100mm General purpose loader bucket; The leading edge of the bucket (frog) is damaged and worn. The bucket is worn, dented, and has multiple weld repairs.
Loader Bucket Cutting Edge, Shanks and Teeth
Worn/damaged edge
Drawbar
This machine is equipped with a rear counterweight.
Specialty - Wheel Loader #1
Oil Sample Analysis
Engine
Hydraulic
Transmission
date of analysis
Feb 03, 2010
Feb 03, 2010
Feb 03, 2010
Silicon
7 PPM
37 PPM
10 PPM
Lead
2 PPM
1 PPM
1 PPM
Tin
0 PPM
0 PPM
0 PPM
Copper
2 PPM
10 PPM
10 PPM
Aluminum
0 PPM
3 PPM
2 PPM
Silver
0 PPM
0 PPM
0 PPM
Nickel
0 PPM
0 PPM
0 PPM
Chromium
0.3 PPM
0.4 PPM
0.4 PPM
Iron
6 PPM
171 PPM
175 PPM
Glycol
N/A
N/A
N/A
Water
0.116
0.046
0.097
Fuel
1.2
N/A
N/A
Note: This condition inspection report is the result of an impartial, systematic, documented process focused on the establishment of the general, overall mechanical condition of a piece of equipment, or of a vehicle, at a specific time. The purpose of the inspection is to establish the "as-is" operational capability of the machine. It is not a performance or load test on the equipment.
Pickup Terms Failure to follow these terms may result in the seller turning away the attempt of your driver to pick up the purchased item.
Buyer will be responsible for any transportation charges issued by the driver.
Location: Fairfield, New South Wales, Australia
Hours: By Appointment
Call at least one day in advance to schedule pickup.
NO LOADING DOCK AVAILABLE: Only RGN and trailers with ramps can be used for pickup.
Driver MUST bring a copy of the IronPlanet Transportation Release to pick the item up.
Powertrain Coverage. Covers major drive train components- engine, torque hubs, transmission & front
and rear axles - and more
Available in North America. May be purchased by residents of U.S. and Mexico only, for equipment operated
within U.S., Mexico or Canada.
OEM parts and service. All repairs are made by an OEM authorized repair facility with genuine OEM replacement
parts installed by OEM trained technicians.