ITEM DETAILS
Meter Reading
7,505 Hours
Serial #
Enclosed Cab, Air Conditioner, Camera, Pressurized Cab, Fire Suppression System, Drill Guidance System, US EPA Label, Sandvik 10 ft Boom, 27 ft Mast, Sandvik Down To Hole Hammer, Rod Changer, Dust Collector, Telescoping Boom, (5) Drill Rods, 16 in Triple Grouser Track Shoes

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Front/side cracked Click here to open photos and videos of this item.  
Exterior Lights Rear lights are not operational Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
(18)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Inoperable
Seat Belts Inoperable; Retract/restrain inoperable
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Current Safety Manual Yes
Current Operator/Maintenance Manual Yes
(4)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Mirrors Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 7,502 hours Click here to open photos and videos of this item.  
Hour Meter 7,505 hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Cab Air Conditioner Operational; After market switch
Cab Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(32)


Engine
Description Rating Details  
Emission Label Photo US EPA Label Click here to open photos and videos of this item.  
Air Conditioning Compressor Operational Click here to open photos and videos of this item.  
Blow-by Visible Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Engine Function Check The engine started and ran.
(18)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check (Drivetrain-Track) The drivetrain was operational without a load.
(3)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Seepage Click here to open photos and videos of this item.  
Valves Dripping leak Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinder(s) Dripping leak on cylinders Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(16)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Main Frame Torsion bar has leaks Click here to open photos and videos of this item.  
Bottom Covers Click here to open photos and videos of this item.  
Kelly Drive Gear Box Dripping leaks Click here to open photos and videos of this item.  
Kelly Slide Wear Plates Click here to open photos and videos of this item.  
Hyd. Hose Carrier System Click here to open photos and videos of this item.  
Vices Click here to open photos and videos of this item.  
Drill Rod Loading System Operational Click here to open photos and videos of this item.  
Drill Rod Racks 8 rod racks; (5) Rods (2) 14', (3) 12'; Rod holder is made for 14' rods only Click here to open photos and videos of this item.  
Dust Collection System Operational, damaged hose Click here to open photos and videos of this item.  
Air Compressor Operational; Hydraulic; Dripping leak Click here to open photos and videos of this item.  
Limited Function Check The main components were operational with damage as noted.
(40)


Undercarriage
Description Rating Details  
Roller Frames Click here to open photos and videos of this item.  
Left Roller Frame Click here to open photos and videos of this item.  
Left Track Tensioner Click here to open photos and videos of this item.  
Left Track Pads Click here to open photos and videos of this item.  
Left Grouser Height 15 mm Click here to open photos and videos of this item.  
Left Track Links Heavy wear and some broken Click here to open photos and videos of this item.  
Left Track Bushings Bushings have not been turned Click here to open photos and videos of this item.  
Left Carrier Rollers Click here to open photos and videos of this item.  
Left Track Rollers Click here to open photos and videos of this item.  
Left Idler Click here to open photos and videos of this item.  
Left Sprocket Click here to open photos and videos of this item.  
Right Roller Frame Click here to open photos and videos of this item.  
Right Track Tensioner Click here to open photos and videos of this item.  
Right Track Pads Click here to open photos and videos of this item.  
Right Grouser Height 15 mm Click here to open photos and videos of this item.  
Right Track Links Heavy wear and several broken Click here to open photos and videos of this item.  
Right Track Bushings Bushings have not been turned Click here to open photos and videos of this item.  
Right Carrier Rollers Click here to open photos and videos of this item.  
Right Track Rollers Click here to open photos and videos of this item.  
Right Idler Click here to open photos and videos of this item.  
Right Sprocket Click here to open photos and videos of this item.  
(28)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Aug 28, 2020 Aug 28, 2020
Silicon 2.46 PPM 4.46 PPM
Tin 0 PPM 0 PPM
Silver 0 PPM 0 PPM
Aluminum 3.01 PPM 1.3 PPM
Chromium 0.75 PPM 0.5 PPM
Lead 1 PPM 0 PPM
Copper 3.7 PPM 17.7 PPM
Nickel 0.17 PPM 0 PPM
Iron 23.3 PPM 5.29 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.