Previous Next
Sold on
20/07/22
Winning Offer
US $250,000
# of Offers
4
# of Watchers
24
SOLD!
ITEM DETAILS
Meter Reading
3,628 Hours
Serial #
Rear View Camera, 2015 US EPA Label, Requires Diesel Exhaust Fluid, 7 ft 06 in Cutting Width, Water System, 34 in Discharge Conveyor, Grade Control System, 12 in Rubber Tracks
** Contact Joe Bruno at +1 (925) 225-8844 or email Jbruno@ritchiebros.com or place offer above **

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Motor Vehicle Safety Standards Label No
CE Mark No CE mark found
Exterior Lights Operational Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
(16)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Not equipped
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(5)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Seats/Armrests Torn Click here to open photos and videos of this item.  
Mirrors Click here to open photos and videos of this item.  
Steering Controls
Hydraulic Controls
Drivetrain Controls
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure No oil pressure indicator
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 3627 hrs Click here to open photos and videos of this item.  
Hour Meter 3628 hrs, Operational hour meter - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted.
(17)


Engine
Description Rating Details  
Engine 2015 US EPA Label, Requires Diesel Exhaust Fluid
Blow-by No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
DEF / AdBlue Tank Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. Click here to open photos and videos of this item.  
Engine #1 Click here to open photos and videos of this item.  
(20)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Drive/Propel Motors Click here to open photos and videos of this item.  
Final Drives
Limited Function Check The drivetrain was operational.
Rotor Drive Clutch
Rotor Drive Pulleys Click here to open photos and videos of this item.  
Rotor Drive Belt Click here to open photos and videos of this item.  
Rotor Final Drive Click here to open photos and videos of this item.  
Rotor Drive Brake
Rotor Shaft Bearings
Limited Function Check The main chassis components functioned.
Main Frame
Track Frame
Rotor Mandrel Click here to open photos and videos of this item.  
Holders and Cutting Bits Click here to open photos and videos of this item.  
Roller Frame Legs
Rotor Compartment Doors Click here to open photos and videos of this item.  
Conveyor Frame Click here to open photos and videos of this item.  
Conveyor Rollers Click here to open photos and videos of this item.  
Collecting Conveyor 34 in Conveyor Click here to open photos and videos of this item.  
Discharge Conveyor Click here to open photos and videos of this item.  
Water Tank Not operationally checked Click here to open photos and videos of this item.  
Water Spray System Not operationally checked
Pressure Washer Not operationally checked
Limited Function Check The main components functioned with minor wear throughout.
Chassis #1 Click here to open photos and videos of this item.  
Chassis #2 Click here to open photos and videos of this item.  
Chassis #3 Click here to open photos and videos of this item.  
Chassis #4 Click here to open photos and videos of this item.  
Chassis #5 Click here to open photos and videos of this item.  
(35)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Cylinder Pins and Bushings
Limited Function Check The hydraulic system was operational.
(25)


Undercarriage
Description Rating Details  
Track links Click here to open photos and videos of this item.  
Pins and Bushings Turned? No Click here to open photos and videos of this item.  
Track Rollers Visible Click here to open photos and videos of this item.  
Idlers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(24)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.