Previous Next
Auction Closed on
4/12/24
Asking Price
CAD 185,000
NOT SOLD
14 watchers
ITEM DETAILS
Meter Reading
6,684 Hours
Serial #
Enclosed Cab, Air Conditioner, Air Ride Seat, Pre-Wired for Grade Control, Topcon C3-A1M Grade Control System, 2011 US EPA Label, Positive Air Shutoff, Eberspacher Engine Coolant Heater, 148 in Wide PAT Blade, Drawbar, 24 in Rubber Tracks
***Seller Comment: Two of the tracks are unused.***


TODAY'S PRICE: CAD $185,000 CAD $222,000 16% OFF


Click here to shop for more discounted items

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark No CE mark found
Hour Meter / Odometer 6684 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Some not operational, top front right most work light lights are not operational Click here to open photos and videos of this item.  
(57)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Operational
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Current Safety Manual Yes
Current Operator/Maintenance Manual Yes
(1)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Mirrors Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Auxiliary Hydraulic Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure No oil pressure indicator
Warning Lights Operational, Check service code light stays on Click here to open photos and videos of this item.  
Gauges Trans temperature gauge did not leave the far left, hydraulic temperature stayed far left as well Click here to open photos and videos of this item.  
Hour Meter 6684 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Cab Air Conditioner The ambient temperature is too cold to check
Cab Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(27)


Engine
Description Rating Details  
Engine 2011 US EPA Label
Emission Label Photo Click here to open photos and videos of this item.  
Air Conditioning Compressor In place; ambient temperature too cold to check operation Click here to open photos and videos of this item.  
Blow-by No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(23)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check (Drivetrain-Track) The drivetrain was operational without a load.
(5)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Not operationally checked, Rear Click here to open photos and videos of this item.  
Blade Lift Cylinders Click here to open photos and videos of this item.  
Blade Angle Cylinders Click here to open photos and videos of this item.  
Blade Tilt Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(17)


Specialty
Description Rating Details  
(4)


Chassis
Description Rating Details  
Blade Condition Click here to open photos and videos of this item.  
Blade Cutting Edge Condition Click here to open photos and videos of this item.  
Push Arm/C-Frame Condition Click here to open photos and videos of this item.  
Push Arm Pivot/C-FrameTrunnions Click here to open photos and videos of this item.  
Tilt Linkage Pins and Bushings Click here to open photos and videos of this item.  
Angle Linkage Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check (dozer) The main components were operational in a limited check.
Frame Condition Click here to open photos and videos of this item.  
Belly pans Click here to open photos and videos of this item.  
(37)


Undercarriage
Description Rating Details  
Left Roller Frame Click here to open photos and videos of this item.  
Left Track Tensioner Click here to open photos and videos of this item.  
Left Track Pads Click here to open photos and videos of this item.  
Left Grouser Height 36, 18 mm Click here to open photos and videos of this item.  
Left Track Links Click here to open photos and videos of this item.  
Left Carrier Rollers Click here to open photos and videos of this item.  
Left Track Rollers Click here to open photos and videos of this item.  
Left Front Idler Click here to open photos and videos of this item.  
Left Rear Idler Click here to open photos and videos of this item.  
Left Sprocket Click here to open photos and videos of this item.  
Right Roller Frame Click here to open photos and videos of this item.  
Right Track Tensioner Click here to open photos and videos of this item.  
Right Track Pads Click here to open photos and videos of this item.  
Right Grouser Height 40, 20 mm Click here to open photos and videos of this item.  
Right Track Links Click here to open photos and videos of this item.  
Right Carrier Rollers Click here to open photos and videos of this item.  
Right Track Rollers Click here to open photos and videos of this item.  
Right Front Idler Click here to open photos and videos of this item.  
Right Rear Idler Click here to open photos and videos of this item.  
Right Sprocket Click here to open photos and videos of this item.  
(51)
 

Oil Sample Analysis
  engine
date of analysis Nov 04, 2024
Silicon 6.48 PPM
Tin 0 PPM
Silver 0 PPM
Aluminum 1.51 PPM
Chromium 0.51 PPM
Lead 0 PPM
Copper 0.74 PPM
Nickel 0.21 PPM
Iron 14.06 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.