Previous Next
Auction Closed on
14/05/25
Asking Price
US $17,500
# of Offers
7
# of Watchers
12
SELLER REVIEWING HIGH OFFER
12 watchers
ITEM DETAILS
Meter Reading
9,039 Hours
Serial #
Air Conditioner, Control Pattern Changer, Tier 4, 10 ft 2 in Stick, Auxiliary Hydraulic Plumbing, 31.5 in Triple Grouser Track Shoes, 60 in Digging Bucket

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


Hydraulics
Description Rating Details  
Excavator_2 #24 Click here to open photos and videos of this item.  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hydraulic Control Pattern Changer Electric actuated, Not operationally tested
Hoses (Hydraulics) Major hydraulic leak coming from under engine compartment while running unknown source Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Capped off, End of stick Click here to open photos and videos of this item.  
Swing Motor Click here to open photos and videos of this item.  
Hydraulic Center Swivel Leaking
Boom Lift Cylinder(s) Click here to open photos and videos of this item.  
Stick Cylinder Click here to open photos and videos of this item.  
Bucket Cylinder Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(24)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drivetrain #5 Click here to open photos and videos of this item.  
Left Drive Motor Some signs of leaking could not operationally test due to low fluid. Click here to open photos and videos of this item.  
Right Drive Motor Some signs of leaking could not operationally test due to low fluid. Click here to open photos and videos of this item.  
Left Final Drive Click here to open photos and videos of this item.  
Right Final Drive Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational as noted., Appears to have low fluid will not drive forward. Weak right and left forward operation.
(5)


General Appearance
Description Rating Details  
CE Mark No CE mark found
Hour Meter / Odometer 9039 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Dented and damaged both sides Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Front lower cracked Click here to open photos and videos of this item.  
Exterior Lights Some not operational, Rear cab lights are not operational Click here to open photos and videos of this item.  
(12)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Operational
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Swing Brake Operational
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Auxiliary Hydraulic Control Not operationally tested Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Dash Console Screen very scratched Click here to open photos and videos of this item.  
Engine Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Warning Lights Operational, Low oil, low hydraulic fluid warning light stays on Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Cab Air Conditioner Not operationally tested due to limited run time because of low oil
Cab Heater Not operationally checked
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(14)


Engine
Description Rating Details  
Engine No US EPA Label Present
Air Conditioning Compressor Not operationally tested Click here to open photos and videos of this item.  
Blow-by No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(10)


Chassis
Description Rating Details  
Boom Condition Click here to open photos and videos of this item.  
Stick Condition Click here to open photos and videos of this item.  
Boom Base Pin and Bushings Click here to open photos and videos of this item.  
Pin and Bushings Boom to Stick Click here to open photos and videos of this item.  
Pin and Bushings Stick to Bucket Heavy movement, Very worn Click here to open photos and videos of this item.  
Turntable Bearing Click here to open photos and videos of this item.  
Bottom Covers Click here to open photos and videos of this item.  
Limited Function Check The main components were operational in a limited check.
(18)


Undercarriage - Excavator
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Left Roller Frame Click here to open photos and videos of this item.  
Left Track Tensioner Not visible
Left Steel Track Shoes Click here to open photos and videos of this item.  
Left Grouser Height 26 mm Click here to open photos and videos of this item.  
Left Track Links Click here to open photos and videos of this item.  
Left Track Pins and Bushings Click here to open photos and videos of this item.  
Left Carrier Rollers Click here to open photos and videos of this item.  
Left Track Rollers Click here to open photos and videos of this item.  
Left Idler Click here to open photos and videos of this item.  
Left Sprocket Click here to open photos and videos of this item.  
Right Roller Frame Click here to open photos and videos of this item.  
Right Track Tensioner Not visible
Right Steel Track Shoes Click here to open photos and videos of this item.  
Right Grouser Height 25 mm Click here to open photos and videos of this item.  
Right Track Links Click here to open photos and videos of this item.  
Right Track Pins and Bushings Click here to open photos and videos of this item.  
Right Carrier Rollers Click here to open photos and videos of this item.  
Right Track Rollers Click here to open photos and videos of this item.  
Right Idler Click here to open photos and videos of this item.  
Right Sprocket Click here to open photos and videos of this item.  
(22)


Specialty
Description Rating Details  
Excavator Bucket Condition Click here to open photos and videos of this item.  
Teeth / Adapters Worn and one missing Click here to open photos and videos of this item.  
(5)
 

Oil Sample Analysis
  engine hydraulic
date of analysis May 05, 2025 May 05, 2025
Silicon 6.34 PPM 7.97 PPM
Tin 0.75 PPM 0 PPM
Silver 0 PPM 0 PPM
Aluminum 1.87 PPM 2.02 PPM
Chromium 0.1 PPM 0.85 PPM
Lead 1.08 PPM 1.07 PPM
Copper 8.05 PPM 0.99 PPM
Nickel 0.04 PPM 0 PPM
Iron 10 PPM 11.15 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.