ITEM DETAILS
Mileage
Not Available
EM Bemac II Generator, 500 KVA, 400 KW, 480 Volts, 3 Phase, Waukesha L1610DSIM Diesel Engine, Diesel Tank, Shelving, Breaker Boxes, Transformers.

*** The Diesel Engine Started And Ran, Could Not Put A Load Test On The Generator***

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
(15)


Control Station
Description Rating Details  
Gauges Click here to open photos and videos of this item.  
Oil Pressure The gauge registers in the operating range.; 35 PSI Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Hour Meter (Start) 632.8 Hours; Hour meter has been replaced can’t confirm how many hours Click here to open photos and videos of this item.  
Limited Function Check (cs) The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(21)


Engine
Description Rating Details  
Fuel Type (Select) Diesel
Emission Control Label (Must Have Legible Photo) None found
Starter Operational
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks Side of engine; Valve cover Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran.
(19)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Make and Model EM Bemac II; Serial#: 174929111 Click here to open photos and videos of this item.  
Emergency Shut Off Switch Not operationally checked
Receptacles Not operationally checked
Limited Function Check (Power Unit) Could not do a load test on generator
(13)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Trailer Brakes Air
Limited Function Check (Brakes) The brakes were not operationally checked.
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Trailer Tire Tread Depth Left front outer: 13/32"; Left front inner: 20/32"; Left rear outer: 16/32"; Left rear inner: 18/32"; Right rear outer: 18/32"; Right rear inner: 8/32"; Right front outer: 16/32"; Right front inner: 12/32"
Wheel Condition
Wheel Studs, Nuts, Lugs
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition Click here to open photos and videos of this item.  
Lights/Wiring Condition All tail lights are missing Click here to open photos and videos of this item.  
Marker Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Brake Lights Functional No
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(15)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.