Meter Reading
9,209 Hours
Serial #
25 kVA/20 kW Rated 3 Phase Output, 240 V / 480 V Rated Voltage, 14.4 kVA,/14.4 kW, Rated Single Phase Output, 240 V / 120 V Rated Voltage, 240 V & 120 V Receptacles, Sound Attenuated, Bottom Mounted Fuel Tank, Denyo DF-0270I2 20 kW Generator, Tier 4, 2016 US EPA Label, Isuzu BZ-4LE2T 4 Cylinder 30 kW 2.17 L Diesel Engine, S/A Trailer, Ball Hitch


**No Title available. Bill of Sale will be provided upon request to transfer ownership**

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Unit Serial Number 7152217 Click here to open photos and videos of this item.  
CE Mark No CE mark found
Hour Meter / Odometer 9209 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
(2)


Generator
Description Rating Details  
Disconnect Switch Not operationally checked Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Operational Click here to open photos and videos of this item.  
Receptacles Not operationally checked Click here to open photos and videos of this item.  
Generator The main components appear to be in place. The generator is producing electrical current.
(6)


Control Station - Small
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Engine Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Fault Indicator Lights Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(5)


Engine
Description Rating Details  
Emission Label Photo Click here to open photos and videos of this item.  
Blow-by Minor Click here to open photos and videos of this item.  
Starter Operational
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(9)


v2 Chassis - Generator
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition Click here to open photos and videos of this item.  
Left Front Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition No visible damage Click here to open photos and videos of this item.  
Lights/Wiring Condition Not operationally checked Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition No visible damage Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(12)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.