ITEM DETAILS
Meter Reading
13,249 Hours
2 Stage Mast, 123 in Lowered Mast Height, 48 in Forks, Side Shift, Perkins 4 Cylinder Diesel Engine

Inspection Report



Please note that you are bidding on an item offered without IronClad Assurance®. Only basic item condition details are provided for your review and consideration in a purchase decision.
 
Deficiencies
Description Details
Deficiencies Deficient Components/Systems Include but are not limited to: There is wear throughout, tilt cylinders are seeping, hydra pump and valves have seepage.

This item is offered as-is, where-is with no IronClad Assurance, and a buyer may not dispute the condition of the item. IronPlanet claims no responsibility for the condition or description of this item. This item does not include any protection offered by IronClad Assurance. A buyer may NOT submit a dispute claim on this item.


General Appearance
Description Rating Details  
Serial Number / VIN No serial number or manufacturer’s identifying number found. This unit may be difficult to export.
Hour Meter / Odometer 13249 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
(11)


Control Station
Description Rating Details  
Limited Function Check The main components are in place and operational as noted. The heater and wipers are inoperable and there is wear throughout. Click here to open photos and videos of this item.  
(9)


Engine
Description Rating Details  
Limited Function Check The engine started and ran.
(8)


Drivetrain
Description Rating Details  
Limited Function Check The drivetrain was operational. Seepage on right outer seal
(7)


Hydraulics
Description Rating Details  
Limited Function Check The hydraulic system was operational. There is seepage at the pump.
(8)


Chassis Photos
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
(21)
 