ITEM DETAILS
Meter Reading
4,273 Hours
Serial #
Enclosed Cab, Air Conditioner, Cat C9 325 hp Diesel Engine, Hydrostatic Drive, 24 in Wide x 15 ft Long Combination Trencher Chain, Crumbling Shoe, Discharge Conveyor, Side Shift, Hydraulic Leveling, 22 in Double Grouser Track Shoes

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


General Appearance
Description Rating Details  
Hour Meter / Odometer 4273 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(22)


Safety
Description Rating Details  
Horn Inoperable
Seat Belts Operational
Safety Lock Out/Stop Inoperable Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Hydraulic gauges are inoperable Click here to open photos and videos of this item.  
Cab Air Conditioner The ambient temperature is too cold to check
Cab Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(9)


Engine
Description Rating Details  
Air Conditioning Compressor In place; ambient temperature too cold to check operation Click here to open photos and videos of this item.  
Blow-by No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(15)


Drivetrain
Description Rating Details  
(15)


Drivetrain - Limited
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(2)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors Not operationally checked Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Bar Lift Cylinders Dripping leak on the right cylinder, Left rusty Click here to open photos and videos of this item.  
Stabilizer Cylinders Click here to open photos and videos of this item.  
Crumber Shoe Cylinder Click here to open photos and videos of this item.  
Chassis Leveling Cylinders Dripping leak on the left cylinder Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
Hydraulics #29 Click here to open photos and videos of this item.  
Hydraulics #30 Click here to open photos and videos of this item.  
Hydraulics #31 Click here to open photos and videos of this item.  
(31)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Trenching Bar Click here to open photos and videos of this item.  
Holders and Cutting Bits Click here to open photos and videos of this item.  
Chain Roller Bushings Click here to open photos and videos of this item.  
Crumber Bar Click here to open photos and videos of this item.  
Chain / Sprocket Condition Worn Click here to open photos and videos of this item.  
Bar Idler Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
Park Brake
Frame Condition
Discharge Conveyor Discharge Both SIdes Click here to open photos and videos of this item.  
(10)


Undercarriage
Description Rating Details  
Track Tensioners It visible
Track Pads Click here to open photos and videos of this item.  
Grouser Height Left Side: 35 mm, Right Side: 35 mm Click here to open photos and videos of this item.  
Track links Click here to open photos and videos of this item.  
Track Rollers Full rock guards. Not visible. Click here to open photos and videos of this item.  
Idlers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(14)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Jul 29, 2024 Jul 29, 2024
Silicon 16.32 PPM 4.52 PPM
Tin 0 PPM 0 PPM
Silver 0 PPM 0 PPM
Aluminum 2 PPM 0.73 PPM
Chromium 0.4 PPM 0.15 PPM
Lead 0 PPM 0 PPM
Copper 0.4 PPM 1.31 PPM
Nickel 1.65 PPM 1.87 PPM
Iron 59.1 PPM 5.31 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.