ITEM DETAILS
Meter Reading
978 Hours
Serial #
Enclosed Cab, Air Conditioner, 2020 US EPA Label, John Deere 6090 6 Cylinder 9.0 L Diesel Engine, Requires Diesel Exhaust Fluid, Hydrostatic Drive, 24 in Wide x 105 in Long Combination Trencher Chain, Crumbling Shoe, Discharge Conveyor, 20 in Double Grouser Track Shoes

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


General Appearance
Description Rating Details  
CE Mark No CE mark found
Hour Meter / Odometer 978 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
(38)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Operational
Current Safety Manual Yes
Current Operator/Maintenance Manual Yes
(1)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Cab Air Conditioner Operational
Cab Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(8)


Engine
Description Rating Details  
Emission Label Photo Click here to open photos and videos of this item.  
Air Conditioning Compressor Operational Click here to open photos and videos of this item.  
Blow-by No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
DEF / AdBlue Tank Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(29)


Drivetrain
Description Rating Details  
(13)


Drivetrain - Limited
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics)
Hydraulic Motors Click here to open photos and videos of this item.  
Valves
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Bar Lift Cylinders Click here to open photos and videos of this item.  
Stabilizer Cylinders Click here to open photos and videos of this item.  
Crumber Shoe Cylinder Click here to open photos and videos of this item.  
Chassis Leveling Cylinders Click here to open photos and videos of this item.  
Track Tilt Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
Hydraulics #29 Click here to open photos and videos of this item.  
(29)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Trenching Bar Click here to open photos and videos of this item.  
Bar Pivot Point Click here to open photos and videos of this item.  
Holders and Cutting Bits Click here to open photos and videos of this item.  
Chain Roller Bushings Click here to open photos and videos of this item.  
Crumber Bar Click here to open photos and videos of this item.  
Chain / Sprocket Condition Click here to open photos and videos of this item.  
Bar Idler Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
Park Brake
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Frame Condition Click here to open photos and videos of this item.  
Discharge Conveyor Click here to open photos and videos of this item.  
(51)


Undercarriage
Description Rating Details  
Track Tensioners Operational
Track Pads Click here to open photos and videos of this item.  
Track links Click here to open photos and videos of this item.  
Pins and Bushings Turned? Click here to open photos and videos of this item.  
Track Rollers Full rock guards. Not visible. Click here to open photos and videos of this item.  
Idlers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(21)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Chassis #43 Click here to open photos and videos of this item.  
Chassis #44 Click here to open photos and videos of this item.  
(2)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.