Previous Next
Sold on
7/11/25
Winning Offer
US $75,000
# of Offers
2
# of Watchers
11
SOLD!
ITEM DETAILS
Mileage
4,039 Hours
VIN
12 in Intake, 10 in Discharge, Centrifugal Water Pump, Detroit 6 Cylinder Diesel Engine, Electric Brakes
Title may not be available for up to 25 business days after auction.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Unit Serial Number 1702417 Click here to open photos and videos of this item.  
Hour Meter / Odometer 4039 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
(2)


Control Station - Small
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Engine Oil Pressure No oil pressure indicator
Fault Indicator Lights Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(3)


Engine
Description Rating Details  
Blow-by Visible Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(9)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Pump Housing Cast Click here to open photos and videos of this item.  
Discharge Check Valve Yes Click here to open photos and videos of this item.  
Limited Function Check (Water Pump) Pump appears functional but was not tested with water.
(5)


Chassis
Description Rating Details  
Frame Rails/ Main Beams Condition No visible damage Click here to open photos and videos of this item.  
Axle Condition Click here to open photos and videos of this item.  
Springs/Hangers Condition Torsion Axle Click here to open photos and videos of this item.  
Brake Lines/Hoses Not operationally checked
Limited Function Check - Brakes The brakes were not operationally checked.
Tyre Condition Click here to open photos and videos of this item.  
Tires Left front outer: 9/32", Left rear outer: 11/32", Right rear outer: 11/32", Right front outer: 10/32"
Wheel Condition
Wheel Studs
Tongue/ Hitch Condition No visible damage Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Power Receptacle Functional Not operationally checked Click here to open photos and videos of this item.  
Lights/Wiring Condition Not operationally checked Click here to open photos and videos of this item.  
Marker Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Brake Lights Functional Not operationally checked Click here to open photos and videos of this item.  
License Plate Light Functional Not operationally checked Click here to open photos and videos of this item.  
(14)
 

Oil Sample Analysis
  engine
date of analysis Jul 03, 2025
Silicon 1.44 PPM
Tin 0.39 PPM
Silver 0 PPM
Aluminum 0.32 PPM
Chromium 0.03 PPM
Lead 0.28 PPM
Copper 0.93 PPM
Nickel 0.21 PPM
Iron 2.88 PPM
Glycol NEG
Water NEG
Fuel
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.